Kodak D-76R

Replenisher for D-76

Water 125F/52C750ml
Metol3g
Sodium Sulfite (anhydrous)100g
Hydroquinone7.5g
Borax (granular)20g
Cold water to make1000ml
Mixing Instructions: Add chemicals in specified sequence.
Dilution: Use undiluted.
Usage: To replenish D-76 or ID-11. For small tank, add 30ml for every 80 sq. in. of film processed. For deep tank, add to tank to maintain level of solution. Discard excess initial developer solution as required.

Notes 

For use as a tank solution replenisher only, not for one-shot use.